+353-1-416-8900REST OF WORLD
+44-20-3973-8888REST OF WORLD
1-917-300-0470EAST COAST U.S
1-800-526-8630U.S. (TOLL FREE)

Water System Biofilm Control and Microbial Monitoring Myths - Webinar (Recorded)

  • Webinar

  • 90 Minutes
  • January 2022
  • NetZealous LLC
  • ID: 3785836

Overview:


It is an unfortunate fact that most water systems today have been designed and are operated and controlled using at least some traditional concepts and methods that are downright wrong.

So how could such traditions become so ingrained and be so wrong? How could well-intentioned benchmarking be so misguided?

There are many reasons, which will be discussed, but regardless of the causes, we need to be aware of these myths and understand how it really should be done. A number of water system myths will be discussed that are related to microbial control approaches as well as microbial monitoring. Each myth will be explained as to its origin and then put into true context with how the supposed microbial control or monitoring approach SHOULD be handled. You will probably be surprised to learn which of your `rules of thumb` are actually quite wrong!

Areas Covered in the Session:


Why water myths develop

  • Impact of c-GMPs
  • Well-meaning but misguided precedents
  • Scientifically unchallenged traditions and benchmarking
  • Rule-hungry culture

Water System Microbial Control Myths

  • WFI from RO
  • Turbulent Flow and Flow Rate
  • Dead Leg Rules
  • Smooth Surfaces
  • In-Line Sterilizing Filters
  • Ozone

Microbial Enumeration Myths

  • Referee Methods
  • Thermophiles in Hot Systems
  • R2A, 35°C, 5 days
  • Test Filter Membrane Rating
  • Compendial Action Levels
  • TOC and Endotoxin as Microbial Count Correlates

Agenda

- Why water myths develop
- Impact of c-GMPs
- Well-meaning but misguided precedents
- Scientifically unchallenged traditions and benchmarking
- Rule-hungry culture
- Water System Microbial Control Myths
- WFI from RO
- Turbulent Flow and Flow Rate
- Dead Leg Rules
- Smooth Surfaces
- In-Line Sterilizing Filters
- Ozone
- Microbial Enumeration Myths
- Referee Methods
- Thermophiles in Hot Systems
- R2A, 35°C, 5 days
- Test Filter Membrane Rating
- Compendial Action Levels
- TOC and Endotoxin as Microbial Count Correlates

Speaker

T.C. Soliis a Ph.D. Microbiologist and President of Soli Pharma Solutions, Inc. and for the past 16 years has offered troubleshooting consulting and training services covering water systems, sterilization, sterile and non-sterile manufacturing, microbiological laboratories, and microbial and beta-lactam contamination control. He has 42 years of pharmaceutical experience as a consultant and with operating companies including DSM Pharmaceuticals, Catalytica Pharmaceuticals, Glaxo Wellcome, Burroughs Wellcome, and Pfizer.


Who Should Attend

  • Validation Managers and Personnel
  • Engineers involved in water System design and Installation
  • Utility operators and their Managers involved in maintaining and sanitizing water systems
  • QA Managers and Regulatory Affairs Personnel involved in defending water system operations and quality data to FDA and EMEA Inspectors and outside Auditors
  • QA Managers and personnel involved in investigations of excursions and preparing CAPAs
  • QC Laboratory Managers and Personnel involved in Sampling, Testing, and Trending Chem and micro data from water systems
  • Consultants and Troubleshooters