Rapid Microbial Tests (RMT) have been long recognized as a potential alternative to USP<71>. CBER has included the potential for RMT as an alternative to a 14-day sterility test even since 21 CFR 610.12 was revised in 2012. However, its use has been limited. Various short shelf-life products to include positron emission tomographic (PET) products, cell, and gene therapies, and compounded sterile preparations (CSPs) prepared for immediate use now require various risk-based rapid microbial approaches. Some products because of their immediate need require real time microbial analyses, whereas other assays would require no more than results within a 48-hour window. The rapid microbial tests (RMT) should be designed so the interested participants can select the preferred technology for their intended use and balance user requirement specifications (URS) including time to result, specificity, limit of detection (LOD), sample size, and product attributes. When a microbial test is conducted, patient safety is best served through the completion of a test that detects microbial contamination prior to product release.
Rapid microbial tests (RMT) should be risk-based (see ICH Q9, Quality Risk Management) so the stakeholder can select the preferred technology for their intended use and balance user requirement specifications (URS) including time to result, specificity, limit of detection (LOD), sample size, and product attributes. For example, many radiopharmaceuticals, due to the short half-life of radiotracers, would benefit most from a real-time microbial test, while CSPs and cell therapy products, due to their short beyond-use dating, would benefit from an overnight test or at least one that is completed within 48 hr.
This webinar discusses the needs of those who manufacture/prepare and test products with a short shelf life and their URS and includes a brief discussion of some suitable methods for risk-based rapid microbial testing for the release of short shelf-life sterile products, e.g., “short-life products”. The webinar will also review elements of USP <1223>, EP 2.6.27, EP 5.1.6, and PDA Test Report #33.
The objective of this live, interactive training Executive Conference Corp webinar is to obtain an enhanced understanding of the new USP General Information Chapter USP <1071> Rapid Sterility Testing of Short Life Products A Risk Based Approach, its inherent method, limitations, sampling quantities, and volumes to assure that the test is being applied as appropriate per United States Pharmacopeia and how to interpret the final result, regardless of whether it represents a pass or a failure. It relies upon USP<71> Sterility Tests to provide background as well as USP<1223> Validation of Alternative Microbiological Methods, Technical Report #33 Evaluation, Validation and Implementation of Alternative Rapid Microbiological Methods and European Pharmacopoeia Chapter 2.6.27 Microbiological Examination of Cell-Based Preparations to guide one through the qualification/validation of a new test method.
Please plan to bring a multi-functional group to gain the most from this webinar.
Webinar Takeaway
- Review of the appropriate media to use for sterility testing.
- Methods of sterility testing.
- Determination of the quantity of each article for testing and why
- Review of sample size considerations
- Issues with sterility testing
- New methodologies for RMT
- Considerations regarding the appropriate technique for testing
- Review of microbiological validation using USP <1223>, EP 2.6.27, EP 5.1.6 and PDA TR #33
Speakers
Dr Barry A. Friedman, Ph.D,
Consultant ,
Cambrex Bio SciencesDr. Friedman possesses over 30 years of industrial managerial experience in various aspects of biopharmaceuticals and medical devices to include regulatory compliance, expert witness testimony, GLP/GMP, quality control, auditing, sterility assurance, microbiological/analytical validations and fermentation technology.
Prior to becoming an independent consultant, Dr. Friedman was associated with Cambrex Bio Sciences, a contract manufacturer of GMP bulk biopharmaceuticals located in Baltimore, Maryland. As the Director of Quality Control, he managed a multi-shift Department of thirty one individuals involved in client management, the receipt and testing of raw materials, environmental monitoring and microbiology, analytical chemistry and QC compliance for the production of Phase 1, 2, 3 and commercial products manufactured from bacteria, yeast and mammalian cells. In this capacity, Dr Friedman enjoyed many client and regulatory interactions, both domestic and international.
Prior to 2000, Dr. Friedman was the Laboratory Director for Chesapeake Biological Laboratories, a contract Aseptic Fill n’ Finish manufacturer located in Baltimore, Maryland. In addition to the professional history listed above, other associations have included W.R. Grace, Sigma Chemical Co., Sherwood Medical, Becton Dickinson, American Cyanamid and Union Carbide.
Dr. Friedman received his B.S. degree in Microbiology from Ohio State University, his M.S. from Michigan State University in Microbial Genetics, and his PhD from Ohio State University in Microbiology.
Who Should Attend
The following individuals or disciplines will benefit from attending this Webinar:
- Quality Assurance
- Quality Control
- Research & Development
- Regulatory Affairs Professionals
- Manufacturing
- Validation
- Metrology
- Auditors